Repositorio Dspace

Eficacia del implante valvular de ahmed para el manejo del glaucoma refractario: seguimiento a 3 años

Mostrar el registro sencillo del ítem

dc.rights.license Attribution 4.0 International (CC BY 4.0) * Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)
dc.contributor.author Martínez Redondo, José Miguel
dc.date.accessioned 2022-02-28T23:35:16Z
dc.date.available 2022-02-28T23:35:16Z
dc.date.issued 2020-05-29
dc.identifier.uri http://repositorio.unisinucartagena.edu.co:8080/xmlui/handle/123456789/454
dc.description.abstract Objetivo: Evaluar la eficacia, seguridad y complicaciones del implante de válvula de Ahmed en pacientes con glaucoma refractario en un periodo de 3 años. Métodos: Revisión retrospectiva de casos consecutivos de pacientes con glaucoma refractario intervenidos mediante implante de válvula de Ahmed entre los años 2014 y 2017. Fueron registradas la agudeza visual, la presión intraocular (PIO), el número de medicamentos antiglaucomatosos y las complicaciones postoperatorias. El éxito completo se definió como una PIO ≥ 6 y ≤ 18 mmHg sin medicamentos, y el éxito calificado, como una PIO ≤ 18 mmHg con uno o más medicamentos. Se definió el fracaso como una PIO > 18 o ≤ 5 mmHg persistente en 2 o más visitas, realización de nuevos procedimientos de glaucoma o pérdida de percepción de luz. Pacientes con un seguimiento inferior a 12 meses fueron excluidos. Resultados: 58 pacientes (60 ojos) fueron incluidos. El seguimiento promedio postoperatorio fue de 19,2 ± 8 meses. 18 ojos (30%) tenían una cirugía previa de glaucoma fallida. La PIO se redujo de una media de 26 mmHg a 13 mmHg en la última visita (p < 0,001). El número de medicamentos antiglaucomatosos tuvo una mediana de reducción de 3,1 a 1,3 en la última visita (p < 0,001). 36 ojos (60%) presentaron una disminución de la AVMC en la visita final. Se consiguió el éxito total en 15 ojos (25%) y 39 ojos (65%) como éxito calificado. 6 ojos (10%) se clasificaron como fracaso. La curva de supervivencia de Kaplan-Meier mostró una probabilidad acumulada de éxito del 90% a los 12 meses y de 58% a los 36 meses. La complicación postoperatoria más frecuente fue la descompensación corneal en 7 ojos (11.6%). Conclusión: Este estudio sugiere que el implante del dispositivo valvular de Ahmed en pacientes con glaucoma refractario es un procedimiento eficaz y seguro para controlar la PIO. Palabras clave: Refractario, Glaucoma, Presión intraocular, Válvula de Ahmed, Cirugía es
dc.description.abstract Objetivo: Evaluar la eficacia, seguridad y complicaciones del implante de válvula de Ahmed en pacientes con glaucoma refractario en un periodo de 3 años. Métodos: Revisión retrospectiva de casos consecutivos de pacientes con glaucoma refractario intervenidos mediante implante de válvula de Ahmed entre los años 2014 y 2017. Fueron registradas la agudeza visual, la presión intraocular (PIO), el número de medicamentos antiglaucomatosos y las complicaciones postoperatorias. El éxito completo se definió como una PIO ≥ 6 y ≤ 18 mmHg sin medicamentos, y el éxito calificado, como una PIO ≤ 18 mmHg con uno o más medicamentos. Se definió el fracaso como una PIO > 18 o ≤ 5 mmHg persistente en 2 o más visitas, realización de nuevos procedimientos de glaucoma o pérdida de percepción de luz. Pacientes con un seguimiento inferior a 12 meses fueron excluidos. Resultados: 58 pacientes (60 ojos) fueron incluidos. El seguimiento promedio postoperatorio fue de 19,2 ± 8 meses. 18 ojos (30%) tenían una cirugía previa de glaucoma fallida. La PIO se redujo de una media de 26 mmHg a 13 mmHg en la última visita (p < 0,001). El número de medicamentos antiglaucomatosos tuvo una mediana de reducción de 3,1 a 1,3 en la última visita (p < 0,001). 36 ojos (60%) presentaron una disminución de la AVMC en la visita final. Se consiguió el éxito total en 15 ojos (25%) y 39 ojos (65%) como éxito calificado. 6 ojos (10%) se clasificaron como fracaso. La curva de supervivencia de Kaplan-Meier mostró una probabilidad acumulada de éxito del 90% a los 12 meses y de 58% a los 36 meses. La complicación postoperatoria más frecuente fue la descompensación corneal en 7 ojos (11.6%). Conclusión: Este estudio sugiere que el implante del dispositivo valvular de Ahmed en pacientes con glaucoma refractario es un procedimiento eficaz y seguro para controlar la PIO. Palabras clave: Refractario, Glaucoma, Presión intraocular, Válvula de Ahmed, Cirugía Abstract: Objective: To assess the efficacy, safety and complications of the Ahmed valve implant in patients with refractory glaucoma over a period of 3 years. Methods: Retrospective review of consecutive cases of patients with refractory glaucoma operated by an Ahmed valve implant between 2014 and 2017. Visual acuity, intraocular pressure (IOP), the number of antiglaucomatous medications and postoperative complications were recorded. Complete success was defined as an IOP ≥ 6 and ≤ 18 mmHg without medication, and qualified success, as an IOP ≤ 18 mmHg with one or more medications. Failure was defined as persistent IOP> 18 or ≤ 5 mmHg at 2 or more visits, new glaucoma procedures, or loss of light perception Patients with a follow-up of less than 12 months were excluded. Results: Results: 58 patients (60 eyes) were included. The average postoperative follow-up was 19.2 ± 8 months. 18 eyes (30%) had previous failed glaucoma surgery. IOP was reduced from a mean of 26 mmHg to 13 mmHg at the last visit (p <0.001). The number of antiglaucomatous medications had a median reduction from 3.1 to 1.3 at the last visit (p <0.001). 36 eyes (60%) presented a decrease in AVMC at the final visit. Total success was achieved in 15 eyes (25%) and 39 eyes (65%) as a qualified success. 6 eyes (10%) were classified as failure. The Kaplan-Meier survival curve showed a cumulative probability of success of 90% at 12 months and 58% at 36 months. The most frequent postoperative complication was corneal decompensation in 7 eyes (11.6%). Conclusions: This study suggests that the implantation of Ahmed glaucoma valvular device in patients with refractory glaucoma is an effective and safe procedure to control IOP. Keywords: Refractory, glaucoma Intraocular pressure, Ahmed valve, Surgery
dc.format Aplicattion/PDF
dc.format.extent 27 páginas
dc.language.iso es es
dc.publisher Universidad del Sinú, seccional Cartagena es
dc.rights El autor, manifiesta que la obra objeto de la presenta autorización es original y la realizo sin violar o usurpar derechos de autor de terceros, por lo tanto, la obra es de exclusiva autoría y tiene la titularidad sobre la misma. PARAGRAFO: En caso de presentarse cualquier reclamación o acción por parte de un tercero en cuanto a los derechos de autor sobre la obra en cuestión, el autor, asumirá toda la responsabilidad, y saldrá en defensa de los derechos aquí autorizados; para todos los efectos la universidad del Sinu, seccional Cartagena actúa como un tercero de buena fe. El autor, autoriza a la Universidad del Sinu, seccional Cartagena, para que los términos establecidos en la Ley 1581 de 2012 en el artículo 30 de la Ley 23 de 1982 y el artículo 11 de la Decisión Andina 351 de 1993 y toda normal sobre la materia, utilice y use la obra objeto de la presente autorización. EL autor declara y autoriza lo dispuesto en el Articulo 10 del Decreto 1377 de 2013 a proceder con el tratamiento de los datos personales para fines académicos, históricos, estadísticos y administrativos de la Universidad del Sinu, seccional Cartagena. De conformidad con lo establecido, aclaramos que “Los derechos morales sobre el trabajo son propiedad de los autores”, los cuales son irrenunciables, imprescriptibles, inembargables e inalienables.
dc.rights.uri http://creativecommons.org/licenses/by-nc/4.0
dc.subject Refractario es
dc.subject Glaucoma es
dc.subject Presión intraocular es
dc.subject Válvula de Ahmed es
dc.subject Cirugía es
dc.title Eficacia del implante valvular de ahmed para el manejo del glaucoma refractario: seguimiento a 3 años es
dc.type Thesis es


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution 4.0 International (CC BY 4.0) * Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO) Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution 4.0 International (CC BY 4.0) * Atribución-NoComercial-SinDerivadas 2.5 Colombia (CC BY-NC-ND 2.5 CO)

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta